Hold the affected lot, preserve the machine event log and map the interruption to the wafer surfaces. Release only after geometry and surface checks show that the affected region meets the same requirements as an uninterrupted cut.

Enclosed diamond wire saw slicing a semiconductor ingot
AI가 생성한 일러스트: 밀폐형 다이아몬드 와이어 톱이 반도체 잉곳을 절단하고 있다.

Map the event before cleaning

Record the stop reason, actual feed position, time, wire motion and whether coolant continued. An emergency stop and a controlled feed hold are not equivalent. Save the last stable signal interval and the return to normal operation. Preserve wafer lane and cutting direction before unloading.

Identify the affected band

Use the machine position as a starting point, not the exact mark location. Wire deflection and recovery mean the cutting interface can lag the feed axis. Compare a profile crossing the suspected band with adjacent areas and an uninterrupted reference wafer. Sample both edge and center lanes on a multi-wire saw.

Conceptual restart line across wafer saw marks
AI로 생성된 일러스트: 웨이퍼 절단 자국을 가로지르는 개념적인 재시작 선.

Choose the disposition

A visible line is not automatically a reject, and a visually clean surface is not automatically acceptable. Compare thickness, waviness, cracks and downstream stock removal against the drawing. Where the damage is uncharacterized, retain samples for cross-section or controlled removal rather than assuming polish will erase the mark.

Qualify planned stops separately

On representative trial material, test the supplier-approved hold and recovery sequence at different engagement depths. Keep unplanned stoppages and broken-wire events outside that qualification. Ask the supplier to demonstrate alarm logging and data export as part of the acceptance run.

Noncontact wafer surface inspection
AI로 생성된 일러스트: 비접촉식 웨이퍼 표면 검사.

관련 엔지니어링 가이드

다음 내용을 참조하세요. 다이아몬드 멀티 와이어 톱 TTV 드리프트 진단 그리고 다이아몬드 와이어 톱 공장 출하 검사(FAT) 가이드 추가 확인을 위해. 다음에서 기계 구성을 비교해 보십시오. ewirexon 제품 목록.

자주 묻는 질문

Can a stopped wire saw always resume?

No. Recovery depends on the alarm, machine design and workpiece condition. Follow the manufacturer-approved procedure.

Does a restart mark prove a crack is present?

No. Inspect the local topography and use a validated damage check where the application requires it.

Which wafers should be sampled?

Include edge and center lanes plus any region indicated by the event log.

Can finishing remove a restart mark?

Only when verified removal fits within the thickness allowance and clears the affected layer.

What should procurement request?

A controlled interruption trial, traceable wafer maps and a clear account of which interruptions are excluded.